Chapter 8 Maintaining Your Array 8-5
2. Depending on whether the cause of the alarm is a failed component or a controller
event and which application you are using, silence the alarm as specified in the
following table.
Note Pushing the Reset button has no effect on controller event alarms and
muting the beeper has no effect on failed component alarms.
TABLE 8-2 Silencing the Alarm
Cause of Alarm To Silence Alarm
Failed Component
Alarms
Use a paperclip to push the Reset button on the right ear of the array.
Controller Event Alarms In the Firmware Application: From the Main Menu, choose “system Functions
Mute beeper.” Refer to the Sun StorEdge 3000 Family RAID Firmware 3.27 User’s
Guide fore more information.
In Sun StorEdge Configuration Service: Refer to “Updating the Configuration”
in the Sun StorEdge Configuration Service 1.3 Users Guide for information about the
“Mute beeper” command.
In the CLI: Run mute [controller].
Refer to the Sun StorEdge 3000 Family CLI 1.6 Users Guide for more information.

Table of Contents

Other manuals for Sun Microsystems StorEdge3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems StorEdge3000 Series and is the answer not in the manual?

Sun Microsystems StorEdge3000 Series Specifications

General IconGeneral
BrandSun Microsystems
ModelStorEdge3000 Series
CategoryStorage
LanguageEnglish

Related product manuals