Appendix H Configuring a Linux Server H-5
5. Press Escape and go back to Configuration Settings. Highlight Selectable Boot
Settings and press Return.
This is where you can make the interface bootable or not bootable.
6. Highlight Select Boot Device. Press the Return key to toggle from disabled to
enabled.
Select Disabled if this is not going to be a bootable device.
Select Enabled if this is going to be bootable device.
7. Press Escape until you get back to Configuration Settings.
8. Highlight Extended Firmware Settings and press Return.
9. On the Extended Firmware Settings menu, highlight Connection Option and press
Return. A screen lists three types of connection:
0 Loop only ----forconnecting to loop type devices
1 Point to point only - - - - for connecting to fabric switches
2 Loop preferred, otherwise point to point
10. If you are connecting to a loop device, highlight 0 and press Return. If you are
connecting to a fabric device or switch, highlight 1 and press Return.
11. Press Escape until a screen is displayed that says “Configuration setting
modified.” Highlight Save changes and press Return.
12. Return to the Fast!UTIL Options. Highlight Scan Fibre Devices and press Return.
This menu option scans all 126 channels to see if there are any devices attached; the
devices are displayed after the scan. If there are no devices attached, it takes some
time to scan. If there are devices attached, the scan usually finds them right away.
13. If you are satisfied with the configuration, press Escape until you get to
Configuration Settings.
14. Highlight Exit Fast!UTIL and press Return.
A screen is displayed that says Exit Fast!UTIL.
15. Highlight Reboot System and press Return.
The server reboots.
H.4 Multiple LUN Linux Configuration
By default, the Linux kernel does not support multiple LUNs. To support multiple
LUNs, modify the kernel with the following steps:

Table of Contents

Other manuals for Sun Microsystems StorEdge3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems StorEdge3000 Series and is the answer not in the manual?

Sun Microsystems StorEdge3000 Series Specifications

General IconGeneral
BrandSun Microsystems
ModelStorEdge3000 Series
CategoryStorage
LanguageEnglish

Related product manuals