A-6 Sun StorEdge 3000 Family Installation, Operation, and Service Manual • May 2004
Electromagnetic Interference
Test Standard
Harmonics Emissions EN 61000-3-2:2000 (No Limits)
Voltage Flicker EN 61000-3-3:1995/A1:2001 (No Limits)
ESD EN 55024 (8kV Contact, 15kV Air)
RF Field EN 55024 (10V/m)
Electrical Fast Transient Burst EN 55024 (1kV I/O, 2kV Power)
Surge EN 55024 (1kV I/O, 1kV Power L-L, 2kV Power L-G)
RF Conducted EN 55024 (3V I/O and Power)
Power Frequency Magnetic Field EN 55024 (N/A monitors only)
Voltage Dip and Interruption EN 55024 (0V/0.5cycle, 70%V/0.5sec, 0V/5sec)
Product Safety Standard