FI SYSTEM DIAGNOSIS 4-65
“C28” (P1655) STV ACTUATOR CIRCUIT MALFUNCTION
INSPECTION
Step 1
1) Lift and support the fuel tank. (5-3)
2) Remove the air cleaner cover. (2-4)
3) Check the STVA lead wire coupler for loose or poor contacts.
4) Turn the ignition switch ON to check the STV operation.
(STV operating order: Full open 95% open)
Is the operating OK?
5) After repairing the trouble, clear the DTC using SDS tool.
(4-27)
DETECTED CONDITION POSSIBLE CAUSE
The operation voltage does not reach the STVA.
ECM does not receive communication signal from
the STVA.
STVA malfunction
STVA circuit open or short
STVA motor malfunction
ECM
STVA. 2B
STVA. 1A
STVA. 1B
STVA
B/Lg
P/W
B
P
G
W/BI
G
W/B
STVA. 2A
1
YES Go to Step 2.
NO
Loose or poor contacts on the STVA coupler
Open or short circuit in the B/Lg, P/W, W/B or
Green wires
If wire and connection are OK, go to Step 2.