EXHAUST SYSTEM 6-7
• Hold the pulley with an adjustable wrench, and then tighten
the pulley mounting bolt to the specified torque.
EXCVA pulley mounting bolt: 5 N·m (0.5 kgf-m, 3.5 lb-ft)
• After connecting the No. 2 cable 8, loosen the lock-nut 9
and turn the adjuster 0 in or out until 16.0 mm (0.63 in) and
more of the thread length D on the cable adjuster can be pro-
vided and tighten the lock-nut 9.
No. 2 cable: 41G0OP
• Tighten the EXCVA mounting bolt to the specified torque.
EXCVA mounting bolt: 10 N·m (1.0 kgf-m, 7.0 lb-ft)
• Install the front footrest assembly.
Front footrest bracket mounting bolt:
23 N·m (2.3 kgf-m, 16.5 lb-ft)
When loosening or tightening the pulley bolt, be sure
to fix the pulley with an adjustable wrench, or EXCVA
may get damaged.
The cable slots of EXCVA pulley must be located
upward (adjustment position). (6-4)