EXHAUST SYSTEM 6-9
• Make the No. 2 cable straight and turn in the cable adjuster 5 fully.
• Loosen the lock-nuts 6 and turn the No.2 cable adjuster 7 in or out until the inner cable length C
becomes 62 – 63 mm (2.44 – 2.48 in).
• After adjusting the inner cable length C, tighten the lock-nuts 6.
• Connect the No. 1 cable and No. 2 cable to the EXCVA pul-
ley. (6-6)
• Check the EXCVA to adjustment position. (6-4)
• Install the pulley 8 to the shaft 9.
NOTE:
Make sure that the shaft’s line D and cable slots E facing
upward as shown.
• Hold the EXCVA pulley with an adjustable wrench, and then
tighten the pulley mounting bolt to the specified torque.
EXCVA pulley mounting bolt: 5 N·m (0.5 kgf-m, 3.5 lb-ft)
Do not use the adjustable wrench to turn EXCVA pul-
ley so as not to cause damage to the internal gear of
EXCVA.
When loosening or tightening the pulley bolt, be sure
to fix the pulley with an adjustable wrench, or EXCVA
may get damaged.
SAMPLE