7-12 COOLING AND LUBRICATION SYSTEM
• Remove the water pump cover 5 and clamp 6.
• Remove the impeller securing bolt by holding the impeller with
a water pump pliers.
• Remove the mechanical seal ring 7 and rubber seal 8 from
the impeller.
• Remove the impeller shaft 9 and washer 0.
• Remove the mechanical seal with the special tool.
09921-20240: Bearing remover set (12 mm)
NOTE:
If there is no abnormal condition, the mechanical seal removal is
not necessary.
The removed mechanical seal must be replaced with a
new one.