PLEASE WAIT…<CR><LF>
F100 L/LOCK/UNLOCK – Remote Lockout
Use function F100 LOCK or UNLOCK to enable/disable remote access to the command line
interface through the network port. Use function F100 L to display the status of Remote
Lockout. Remote Lockout can also be set using F100 on the keypad interface. The factory
setting is “Unlocked”. To unlock remote lockout, use the keypad or the serial port’s command
line interface (The network port is not available because it has been locked).
Warning: F100 L and F100 LOCK terminates any active network sessions and
prevents future network sessions. To unlock F100 L or F100 LOCK, use
the serial port command line interface or the keypad display.
To lock the unit from a remote location, enter:
F100 LOCK<CR>
where:
F
= ASCII character F
100
= unit function number
<S>
= space
LOCK
= specify LOCK command
<CR>
= input line terminator
For example, enter:
F100 LOCK<CR>
To users on the serial port, XL-GPS responds:
OK<CR><LF>
Or, to users on the network port, XL-GPS gives the following response and then closes the
port:
GOODBYE.<CR><LF>
To unlock remote lockout, use the command line interface on the serial port to enter:
F100 UNLOCK<CR>
Or use the keypad’s F100.
Page 114 of 221 .................................098-00116-000 Rev. A

Table of Contents

Other manuals for Symmetricom XL-GPS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XL-GPS and is the answer not in the manual?

Symmetricom XL-GPS Specifications

General IconGeneral
BrandSymmetricom
ModelXL-GPS
CategoryReceiver
LanguageEnglish

Related product manuals