F100 Network Port Configuration & XL-GPS Firmware
F100 L Remote Lockout Status
Command Line Only Not available in keypad.
Use function F100 L to display the status of the remote lock. For more information, see F100
LOCK above.
To view the lock setting for remote access, enter:
F100 L<CR>
where:
F
= ASCII character F
100
= unit function number
<S>
= space
L
= specify L command
<CR>
= input line terminator
XL-GPS responds:
F100 L LOCKED<CR><LF>
or
F100 L UNLOCKED<CR><LF>
F100 ST Self Test Status
Use function F100 ST to display whether the Self Test Status parameters passed or failed.
The parameters include: flash-memory checksum test, nonvolatile (NV) RAM, Serial Port,
and version check.
To query the self-test status, enter:
F100<S>ST<CR>
where:
F
= ASCII character F
100
= unit function number
<S>
= space
098-00116-000 Rev. A............................... Page 115 of 221