5: Function Reference
F6 – Keypad Lock
F6 – Keypad Lock enables or disables the keypad, preventing accidental changes to the XL-
GPS’s settings. When enabled, the display responds ‘KEYPAD LOCKOUT BY FUNC 6’
when the user attempts to access any function other than F6. F6 remains available through
the keypad at all times. The factory setting for F6 – Keypad Lock is disabled.
See "Factory Default Jumper and Switch Settings for Options" on page 166
Command Line
To display the Keypad Lock status, send:
F6<CR>
XL-GPS responds:
F6<S><STATE><CR><LF>
where:
F
= ASCII character F
6
= function number
<S>
= ASCII space character (one or more)
<STATE>
= ENABLE or DISABLE
<CR>
= carriage return character
<LF>
= line feed character
For example, to display the Keypad Lock status, send:
F6<CR>
XL-GPS responds:
F6 DISABLE<CR><LF>
To enable Keypad Lock, send the following string:
F6 ENABLE<CR>
XL-GPS responds:
OK<CR><LF>