F5 – Time-Quality Setup
F
= ASCII character F
05
= function number
<S>
= ASCII space character (one or more)
<SEP>
= one or more separator characters; either space, comma or tab
<STATE>
= ENABLE or DISABLE
<FLAG>
= one error threshold in nanoseconds, 1 to 11 digits with or without leading zeros
<CR>
= carriage return character
<LF>
= line feed character
For example, to display the time quality status and flags, enter:
F5<CR>
If F5 is enabled, XL-GPS responds (example):
F5 ENABLE 00000001000 00000010000 00000100000 00001000000<CR><LF>
If F5 is disabled, XL-GPS responds:
F5 DISABLE<CR><LF>
To enable time quality reporting, and change the thresholds of the time quality flags, enter:
F5 ENABLE 2000 20000 200000 2000000<CR>
XL-GPS responds:
OK<CR><LF>
Note: Leading zeros aren’t required when entering new settings. They are displayed in the
readouts.
To disable time quality reporting:
F5 DISABLE<CR>
XL-GPS responds:
OK<CR><LF>
098-00116-000 Rev. A............................... Page 57 of 221