1.2.5.4 Using the safety functions
Attention
Activating SBC independently of or with a delay to STO is not possible.
When STO is active SBC will also be activated, if a brake is connected it will be engaged.
To prevent damaging the brake, a Safe Stop Category 1 (SS1) is recommended.
1.2.5.4.1 Timing diagrams
1.2.5.4.1.1 Timing diagram for STO-function without connected brake
Synapticon Documentation