3.1.9.1.145 0x6087 Torque slope
Configures the rate of change of torque. The units are in per thousand of rated torque per second.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Torque slope 0x6087:0 UDINT 32 0 readwrite Receive