1.2.6.4.1 Safety specifications
1.2.6.4.1.1 System requirements
Required Firmware
v4.2.0 or higher
Supported Hardware
SOMANET Circulo 7
SOMANET Circulo 9
1.2.6.4.1.2 Technical specifications
Safety parameters
Safety Integration level (SIL) according to IEC
61508:2010
SIL 3
Performance Level (PL) according to ISO 13849-
1:2015
PL e cat. 3
Safe Failure Fraction (SFF) TBD
Probability of dangerous failure per hour (PFH ) TBD
Probability of dangerous failure on demand (PFD ) TBD
Common Cause Failure (CCF) TBD
Hardware Fault Tolerance (HFT) 1
Reaction time 10 ms
De-activation time 10 ms
Mean Time to dangerous Failure (MTTF ) TBD
Diagnostic coverage (DC ) TBD
HW-type Type A
Mission time T TBD
Supported safety modes High, Low
Installation requirements
Max. installation altitude 2000 m
d
avg
d
avg
M
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 201/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node 400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node 400 and is the answer not in the manual?

SYNAPTICON SOMANET Node 400 Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node 400
CategoryServo Drives
LanguageEnglish

Related product manuals