3.1.9.1.86 0x2213 GPIO position trigger
Configure a GPIO to output a width-configurable pulse everytime certain encoder position is reached.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Position setpoint 0x2213:1 DINT 32 0 Inc readwrite Receive
PDO
(Outputs)
Position value at which the GPIO shpould be triggered.
Name Index:Sub Type Bit
Size
Options Unit Access PDO
Mapping
Encoder
connector
0x2213:2 USINT 8
Encoder Connector 1 0
Encoder Connector 2 1
Encoder Connector 3 2
Encoder Connector 4 3
readwrite
Connector where the encoder whose position is used for this feature is connected.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Pulse width 0x2213:3 USINT 8 0 ms readwrite
Width of the pulse when the GPIO is triggered.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 728/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node 400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node 400 and is the answer not in the manual?

SYNAPTICON SOMANET Node 400 Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node 400
CategoryServo Drives
LanguageEnglish

Related product manuals