3–1
Section 3
Installation
This section of the manual provides the information necessary to install the
1730-Series monitor in its operating environment. Information contained here
provides electrical and mechanical installation, plus settings for the internal
jumpers and descriptions of the available, optional cabinets.
The shipping carton and pads provide protection for the instrument during
transit, they should be retained in case subsequent shipment becomes necessary.
Repackaging instructions can be found in Section 6 (Maintenance) of this
manual.
Electrical Installation
This instrument is intended to operate from a single-phase power source with
one current-carrying conductor at or near earth-ground (the neutral conductor).
Only the Line conductor is fused for over-current protection. Systems that have
both current-carrying conductors live with respect to ground (such as phase-to-
phase in multiphase systems) are not recommended as power sources.
This section of the manual provides the information necessary to install the
1730-Series monitor in its operating environment. Information contained here
provides electrical and mechanical installation, plus settings for the internal
jumpers and descriptions of the available, optional cabinets.
All members of the 1700-Series instrument line operate over a frequency range
of 48 to 66 Hz, at any mains voltage between 90 Vac and 250 Vac. These newer
versions of the 1730-Series instruments do not require any internal changes to
select their operating voltage range.
Operating Options
Not all installations are identical. In order to make operation of the 1730-Series
Waveform Monitor as flexible as possible there are internal jumpers that can be
changed to provide operating flexibility. For example, it is possible to select
either the 3-step or 4-step parade to accommodate RGB or YRGB displays.
With the exception of the 50-60 Hz jumper, the factory preset position is
Packaging
Power Source
Mains Frequency and
Voltage Ranges