Performance Tests
Equipment Required (see Table
B1):
Calibration Generator (Item
1)
Leveled
Sine-Wave
Generator (Item 2)
50 n
ENC
Coaxial Cable (Item
7)
Dual
Input
Coupler (Item 8)
50 n
ENC
Termination (Item 11)
lOX
ENC
Attenuator
(Item 13)
ENC
Male-to-Tip Plug (Item 14)
Initial Control Settings
Vertical
(CH
1
and
CH
2)
POSITION .....................................
Midrange
(CH1
and
CH2)
MODE ............................................ CH 1
VOLTS/DIV ................................... 2 mV
(CHl
and
CH2)
VARiable ....................................... Off
(CHl
and
CH2)
AC-GND-DC ..................................
DC
(CHl
and
CH2)
Horizontal
POSITION .....................................
Midrange
MODE ALT MAGN ....................... Off
SEC/DIV ......................................... 0.5
ms
V ARiable ....................................... Off
X1, XlO, X50
Magnifier
................
Xl
Trigger
HOLDOFF ...................................... MIN
LEVEL ............................................
Midrange
SLOPE ............................................
Positive
Going
MODE ............................................ P-P AUTO
SOURCE ........................................ VER
Ti
cal
MODE
COUPLING ....................................
DC
2212
User
Manual
C-9

Table of Contents