6. COORDINATE MEASUREMENT
6-8
Manual Operation
[Example] : Setting 3 Dimensional measurement, 1 set of inverted measurement at the position of
telescope in normal and inverted.
Confirm instrument mode is angle or distance measurement mode.
Operating procedure Operating key Display
Press [F4]() key 4 times to be a
function as in page 5.
[F4]
4 times
V: 90
10
'
20
"
HR : 120
30
'
40
"
0SET HSET R/L 1
BS CSET RST 5
Press [F3](RST) key.
[F3]
RESECTION
F1: 2D
F2: 3D
Press [F2](3D) key. *1)
(The instrument height which already
entered by the soft key (CSET) will be
displayed.)
Enter the instrument height and press
[ENT] key.
(If the value is accepted, press [ENT]
key as it is.)
[F2]
Input Inst.HT
[ENT]
I
N
S. HT I
N
PUT
0.0000 m
EXIT
CLR
I
N
S. HT I
N
PUT
1.3000 m
EXIT
CLR
SET O
K
[ YES ][ NO ]
Confirm the instrument height, press
[F3](YES) key. *2)
Enter the coordinate value of known
point A and Prism height, and press
[ENT] key.
[F3]
Input N data
[ENT]
Input E data
[ENT]
Input Z data
[ENT]
Input Prism HT
[
ENT
]
POINT A
N :
.

m
E :
.

m
EXIT
CLR

POINT A
Z :
.

m
R . HT :
.

m
EXIT
CLR

Enter the coordinate value of known
point B and Prism height, and press
[ENT] key.
Input N data
[ENT]
Input E data
[ENT]
Input Z data
[ENT]
Input Prism HT
[ENT]
POINT B
N :
.

m
E :
.

m
EXIT
CLR

POI
N
TB
N
:
.

m
E:
.

m
EXIT
CLR
SET OK
[ YES ][ NO ]
Press [F3](YES) key. [F3]
V: 90
10
'
20
"
HR : 120
30
'
40
"
POI
N
TA
[ SET ]