6. COORDINATE MEASUREMENT
6-4
6.2.2. Resection Method
The coordinate value of the instrument point can be set from the coordinate value and measured
data of 2 known points. There is 2 setting methods that is auto collimating method and manual
collimating method. It is also available to select 2 Dimensional or 3 Dimensional measurement and
the setting which measured by normal telescope position or normal/inverted telescope positions.
For the selection of auto or manual methods requires preset of "15. special mode (menu key
operation)"
Auto collimating method
[Example] Setting 3 Dimensional measurement, 1 set at the position of telescope normal /
inverted measurement.
Confirm mode is angle or distance measurement.
Operating procedure Operating key Display
Press [F4]() key 4 times to be a
function as in page 5.
[F4]
4 times
V: 90
10 '20"
HR : 120
30' 40"
0SET HSET R/L 1
BS CSET RST 5
Press [F3](RST) key. [F3]
RESECTION
F1: 2D
F2: 3D
Press [F2](3D) key. 1)
(The instrument height which already
entered by the soft key (CSET) will be
displayed.)
[F2]
I
S. HT I
PUT
0.0000 m
EXIT
CLR
Enter the instrument height and press
[ENT] key.
(If the value is accepted, press [ENT]
key as it is.)
Input Inst.HT
[ENT]
I
S. HT I
P
T
1.3000 m
EXIT
CLR
SET O
YES
O
Confirm the instrument height, press
[F3](YES) key.
2)
Enter the coordinate value of known
point A and Prism height, and press
[ENT] key.
[F3]
Input N data
[ENT]
Input E data
[ENT]
Input Z data
[ENT]
Input Prism R.HT
[ENT]
POINT A
N :
.
m
E :
.
m
EXIT
CLR
POINT A
Z :
.
m
R . HT : . m
EXIT CLR
POINT B
N :
.
m
E :
.
m
EXIT
CLR