15. SPECIAL MODE (MENU KEY OPERATION)
15-3
5) TRK SPEED: Setting tracking speed(Refer to Chapter 7.3 "Setting tracking parameter").
Setting automatic aiming accuracy or tracking function to the traveling objects in
Tracking mode.
Selecting items Setting speed
LOW Low speed
MEDIUM Medium speed
HIGH High speed
Setting value at shipping time from factory is MEDIUM.
6) TRK SENSITIV: Setting Tracking detecting sensitivity(Refer to Chapter 7.3 "Setting
tracking parameter").
Select “Medium" or “Low" sensitivity to avoid affection extra reflectors other than prism.
Selecting items Setting speed
HIGH High sensitivity
(Normal setting)
MEDIUM Medium sensitivity
LOW Low sensitivity
Setting value at shipping time from factory is HIGH.