EasyManua.ls Logo

Topcon HiPer Lite - Page 87

Topcon HiPer Lite
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Surveying with the Receiver
P/N 7010-0557 www.topconpositioning.com
3-7
LED blink mode switch – enable to start and stop static
data recording using the FN key
Figure 3-2. Configuration->Receiver->MINTER
3. Click the Advanced tab and then the Multipath tab, set the
following parameters, then click Apply (Figure 3-3):
Code multipath reduction – enable
Carrier multipath reduction – enable
Figure 3-3. Advanced->Multipath