Surveying with the Receiver
P/N 7010-0557 www.topconpositioning.com
3-7
• LED blink mode switch – enable to start and stop static
data recording using the FN key
Figure 3-2. Configuration->Receiver->MINTER
3. Click the Advanced tab and then the Multipath tab, set the
following parameters, then click Apply (Figure 3-3):
• Code multipath reduction – enable
• Carrier multipath reduction – enable
Figure 3-3. Advanced->Multipath