Multi Pro 1750
Page 5 − 13
Electrical System
Main Menu Screen
The main menu screen (Fig. 14) is accessed from the In-
foCenter main information screen. Press any button
once to expose the navigation pane, then press the cen-
ter/down button again (as indicated by the
in the
navigation pane). The main menu screen provides ac-
cess to the following screens:
S Calibration
S Settings
S Service
S Diagnostics
S About
Press the center/down button (as indicated by the
at
the bottom of the screen) to highlight the desired menu
item, then press the left/forward button (as indicated by
the
at the bottom of the screen) to enter the high-
lighted menu item.
To return to the previous screen, press the left/back but-
ton (as indicated by the at the bottom of the screen).
1. Menu screens
2. Left/back button
3. Center/down button
4. Right/forward button
Figure 14
2
3
4
Main Menu
Calibration
Settings
Service
1
MAIN MENU SCREEN
Calibration Screen
Use the calibration screen (Fig. 15) to calibrate the
sprayer flow, speed, and boom bypass if you change the
nozzles, or as needed (see machine Operator’s Manu-
al). Press the center/down button (as indicated by the
at the bottom of the screen) to highlight the desired
menu item, then press the left/forward button (as indi-
cated by the
at the bottom of the screen) to enter the
highlighted menu item.
To return to the previous screen, press the left/back but-
ton (as indicated by the
at the bottom of the screen).
Test Speed: Vehicle speed is an element necessary to
calculate and maintain the desired application rate. Use
the right/forward button (as indicated by the at the
bottom of the screen) to enter a vehicle speed when stat-
ic testing the spray system (ie: boom bypass valve ad-
justment).
Flow Calibration: Product flow/volume is an element
necessary to calculate and maintain the desired appli-
cation rate. Use the right/forward button (as indicated by
the
at the bottom of the screen) to begin the process
of calibrating the flow meter flow/volume sensor.
Speed Calibration: Vehicle speed is an element neces-
sary to calculate and maintain the desired application
rate. Use the right/forward button (as indicated by the
at the bottom of the screen) to begin the process of
calibrating the vehicle speed sensor.
1. Calibration items
2. Left/back button
3. Center/down button
4. Right/forward button
Figure 15
2
3
4
Calibration
Test Speed:
Flow Cal:
0.0
Speed Cal:
1
Use Flow Calibration Default: Use the right/forward
button (as indicated by the
at the bottom of the
screen) to reset the flow calibration to the default calcu-
lated average, not the actual volume. The actual volume
is the result of the flow calibration process.
Use Speed Calibration Default: Use the right/forward
button (as indicated by the
at the bottom of the
screen) to reset the speed calibration to the default cal-
culated average, not the actual speed. The actual speed
is the result of the speed calibration process.