Multi Pro 1750Page 9 − 18Ultra Sonic Boom Kit (Optional)
Troubleshooting Chart
The chart that follows contains suggestions that can be
used to assist in diagnosing Ultra Sonic Boom System
performance issues. These suggestions are not all−in-
clusive. Also, consider that there may be more than one
cause for a machine problem.
NOTE: When troubleshooting an electrical problem on
your Ultra Sonic Boom System, refer to information re-
garding the sonic boom light and the diagnostic light in
this chapter.
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
Problem
Possible Cause
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
Light in sonic boom switch is not illu-
minated.
Sonic boom switch is in the MANUAL position.
Fuse D (2 amp) in sonic boom fuse block is faulty (all sonic boom
functions are affected).
Fuse B (10 amp) in sonic boom fuse block is faulty.
Electrical power from vehicle is not available (all sonic boom func-
tions are affected).
Sonic boom switch or circuit wiring is faulty.
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
One of the boom lift cylinders will not
extend or retract.
Boom lift switch or circuit wiring for affected lift cylinder is faulty.
Boom lift control manifold solenoid coil or circuit wiring for affected
lift cylinder is faulty.
A hydraulic problem exists with the lift cylinder, boom lift control
manifold or other hydraulic component.
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
Neither of the boom lift cylinders will
extend or retract.
Fuse(s) in sonic boom fuse block is faulty.
Electrical power from vehicle is not available (all sonic boom func-
tions are affected).
A hydraulic problem exists with the lift cylinders, boom lift control
manifold or another hydraulic component.
The Toro Electronic Controller (TEC) or circuit wiring is faulty.
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
The LED’s on one of the sonic boom
sensors are not illuminated.
Sonic boom sensor or circuit wiring is faulty.
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁ
The LED’s on both of the sonic
boom sensors are not illuminated.
Sonic boom switch is in the MANUAL position.
Fuse A (10 amp) in sonic boom fuse block is faulty.
Sonic boom switch or circuit wiring is faulty.