EasyManua.ls Logo

Toro Reelmaster 5010- H - Fault 38: CAN Bus Fault-CRM 1

Toro Reelmaster 5010- H
476 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault38:CANBusFault—CRM1
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____ FAULT#38 _____
CAN 1
FaultDescription
TheTEC-5002lostorneverestablishedcommunicationwiththecuttingreelmotor1ontheCANbus.
CircuitDescription
All5cuttingreelmotorsareconnectedonthe48VdcCANbus.All5cuttingreelmotorsfunctionsimultaneously.
When1cuttingreelmotorisaffectedbyaCANbusfault,allofthecuttingreelmotorsaredisabledandthe
machineisunabletomow.
ConditionsforSettingtheFault
ThisfaultisreportediftheTEC-5002losescommunicationwiththecuttingreelmotorfor1.5seconds.If
communicationisneverestablished,afaultisreported2.5secondsafterpowerisrstturnedon.
Note:Thisfaultisprobablyincludedamongallofthecuttingreelmotorssettingrelatedfaultsinrapid
succession.Beginthediagnosiswiththerstcuttingreelmotortoreportafault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Inspectthewiringforcuttingreelmotor1.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.
2.Unplugthe48Vdcbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnecting
andDisconnectingthe48VdcBatterySystem(page19).
3.RefertoFigure80tolocatecuttingreelmotor1.
118

Table of Contents

Other manuals for Toro Reelmaster 5010- H

Related product manuals