EasyManua.ls Logo

Toro Reelmaster 5010- H - Fault 68: Speed Stall-CRM 4

Toro Reelmaster 5010- H
476 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault68:SpeedStall—CRM4
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
Note:Thisfaultcanoccurduringheavycuttingconditionsorasaresultofacuttingunitmalfunction.Askthe
machineoperatorforinformationregardingcuttingconditionswhenthefaultoccurred.
InfoCenterDisplay:
_____ FAULT#68 _____
StallSpeed 4
FaultDescription
Thecuttingreelmotoroncuttingunit4stalled.
CircuitDescription
All5cuttingreelmotorsandthemotor/generatorarelinkedonthe48VdcCANbuscircuit.
ConditionsforSettingtheFault
Ifthecuttingreelmotorisactive,yetremainsat0rpmformorethan3seconds,thefaultisreported.
Note:Checkforfault73(HighTempWarning—CRM4),asanoverheatedcuttingreelmotororacuttingreel
motorstallcouldbeacontributingfactortoastallspeedfault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
WARNING
Contactwiththecuttingreelsorothermovingpartscanresultinpersonalinjury.
Keepngers,hands,andclothingawayfromthecuttingreelsorothermovingparts.
Neverattempttoturnthecuttingreelsbyhandwhiletheengineisrunning.
Step2:Checkcuttingunit4foranydebriscloggingthereel.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.
241

Table of Contents

Other manuals for Toro Reelmaster 5010- H

Related product manuals