Fault101:OverCurrentDisable—CRM2
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____ FAULT#101 _____
HI Disable 2
FaultDescription
Cuttingreelmotor2hasdetectedexcessivecurrentdrawandhasbeendisabled.
CircuitDescription
Eachcuttingreelmotorhasaninternalvoltageregulator.
ConditionsforSettingtheFault
Cuttingreelmotor2hasdetectedexcessivecurrentdrawandhasbeendisabled.
Note:ChecktheInfoCenterforfault66(SpeedStall—CRM2)orfault71(HighT empWarning—CRM2),asan
overheatedcuttingreelmotororacuttingreelmotorstallcouldbeacontributingfactortoafault101.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Swapcuttingreelmotorsbetweencuttingunits.
Allofthecuttingreelmotorsareidentical.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.
2.Unplugthe48Vdcbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnecting
andDisconnectingthe48VdcBatterySystem(page19).
3.Swapcuttingreelmotor2withacuttingreelmotorfromadifferentcuttingunit.Youcanobtainmore
informationonreplacingthecuttingreelmotorinChapter5ofthe5010-HServiceManual.
4.Pluginthe48Vdcbatterydisconnect.RefertoConnectingandDisconnectingthe48VdcBatterySystem
(page19).
5.Operatethemachine.
393