Fault84:48VKeySwitchOvervolt—CRM3
Important:Forthisfault,theterm“keyswitch”referstothe48Vdclogicpowercircuit,nottothe
ignitionswitch.
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____ FAULT#84 _____
48V HIV 3
FaultDescription
Cuttingreelmotor3hasdetectedthatthe48Vdclogicvoltagehasexceededthehighvoltagelimit.This
faultcausesthecuttingreelmotortobedisabled.
Note:All48Vdcdevicesareconnectedtothesame48Vdcbus.Ifthisisasystemissue,theTEC-5002
combinesall648VdcKeySwitchOvervoltfaults(faults82through87)intoasinglefault(code31,48VdcKey
SwitchOvervolt).
CircuitDescription
All5cuttingreelmotorssharethe48Vdclogicpowerwiththemotor/generator.
ConditionsforSettingtheFault
Cuttingreelmotor3hasdetectedthatthe48Vdclogicvoltagehasexceededthehighvoltagelimitof67.5Vdc.
Note:ThisfaultcanalsooccuriftheTEC-5002losescommunicationwiththemotor/generatorandreverts
tolimpmode.WhentheTEC-5002losescommunication,itlosesenginespeedcontrol,andthemechanical
governorlimitsenginespeedto3,200rpm.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Determinethetroubleshootingstrategy.
Ifonly1cuttingreelmotorisreportinga48VKeySwitchOvervoltfault,theproblemismorelikelytobewiththe
48Vdclogicpowerconnectiontothatcuttingreelmotor.GotoStep3.
321