Fault70:HighTempWarning—CRM1
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____ FAULT#70 _____
Warning 1
FaultDescription
Ahightemperaturewarningexistsforcuttingreelmotor1.
CircuitDescription
Temperaturesensorsmonitorcomponentsinsidethecuttingreelmotortoprotectthemfromhightemperature
damage.Thecuttingreelmotorcontrollerreducesthecurrenttothecuttingreelmotorinresponsetotherising
temperature,whicheventuallystopsthecuttingreelmotorifthetemperaturekeepsrising.
Note:Asideeffectofthisfaultisreducedreelspeedandanincreasedchanceofafault65,SpeedStall—CRM
1.
ConditionsforSettingtheFault
Thisfaultistriggeredwhenanexcessiveloadonthecuttingreelmotorcausesthetemperatureinsidethe
cuttingreelmotortoexceed194°F(90°C).Ifthetemperatureinsidethecuttingreelmotorreaches212°F
(100°C),thecuttingreelmotorisshutoff.
Note:Asktheoperatoraboutthemowingconditionswhenthefaultoccurred.
Note:Afaultytemperaturesensorinthecuttingreelmotordoesnotcausethisfault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Ifthefaultrepeats,gotoStep2.
Step2:Attempttocooloffthecuttingreelmotorwhilemowing.
1.RefertoFigure134tolocatecuttingunit1.
251