Fault8:12VdcChargingSystemVoltage
TooHigh
InfoCenterDisplay:
_____ FAULT#8 _____
ChargingHI
FaultDescription
TheTEC-5002hasdetectedthatthe12Vdcchargingsystem(alternator)isgeneratingavoltagemorethan
16.3Vdc.
CircuitDescription
A12Vdcbatterymountedattherearofthemachineandtheenginealternatorprovidesystemelectricalpower.
ConditionsforSettingtheFault
TheTEC-5002detectedthatthe12Vdcchargingsystem(alternator)isproducingavoltagethatistoohigh.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Testthealternator.
Thealternatorislocatedattheright-handsideoftheengine,neartherearofthemachine.SeeFigure31.
49