Fault69:SpeedStall—CRM5
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
Note:Thisfaultcanoccurduringheavycuttingconditionsorasaresultofacuttingunitmalfunction.Askthe
machineoperatorforinformationregardingcuttingconditionswhenthefaultoccurred.
InfoCenterDisplay:
_____ FAULT#69 _____
StallSpeed 5
FaultDescription
Thecuttingreelmotoroncuttingunit5stalled.
CircuitDescription
All5cuttingunitsandthemotor/generatorarelinkedonthe48VdcCANbuscircuit.
ConditionsforSettingtheFault
Ifthecuttingreelmotorisactive,yetremainsat0rpmformorethan3seconds,thefaultisreported.
Note:Checkforfault74(HighTempWarning—CRM5),asanoverheatedcuttingreelmotororacuttingreel
motorstallcouldbeacontributingfactortoastallspeedfault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21)
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
WARNING
Contactwiththecuttingreelsorothermovingpartscanresultinpersonalinjury.
Keepngers,hands,andclothingawayfromthecuttingreelsorothermovingparts.
Neverattempttoturnthecuttingreelsbyhandwhiletheengineisrunning.
Step2:Checkcuttingunit5foranydebriscloggingthereel.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.