EasyManua.ls Logo

Toro Reelmaster 5010- H - Fault 73: High Temp Warning-CRM 4

Toro Reelmaster 5010- H
476 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault73:HighTempWarning—CRM4
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____ FAULT#73 _____
Warning 4
FaultDescription
Ahightemperaturewarningexistsforcuttingreelmotor4.
CircuitDescription
Temperaturesensorsmonitorcomponentsinsidethecuttingreelmotortoprotectthemfromhightemperature
damage.Thecuttingreelmotorcontrollerreducesthecurrenttothecuttingreelmotorinresponsetotherising
temperature,whicheventuallystopsthecuttingreelmotorifthetemperaturekeepsrising.
Note:Asideeffectofthisfaultisreducedreelspeedandincreasedchanceofafault68,SpeedStall—CRM4.
ConditionsforSettingtheFault
Thisfaultistriggeredwhenanexcessiveloadonthecuttingreelmotorcausesthetemperatureinsidethe
cuttingreelmotortoexceed194°F(90°C).Ifthetemperatureinsidethecuttingreelmotorreaches212°F
(100°C),thecuttingreelmotorisshutoff.
Note:Afaultytemperaturesensorinthecuttingreelmotordoesnotcausethisfault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Attempttocooloffthecuttingreelmotorwhilemowing.
1.RefertoFigure137tolocatecuttingunit4.
266

Table of Contents

Other manuals for Toro Reelmaster 5010- H

Related product manuals