Fault58:M/GCurrentSensorFailure
InfoCenterDisplay:
_____ FAULT#58 _____
CurrentSensor
FaultDescription
Oneofthe3currentsensorsinsidethemotor/generatorcontrollerhasfailed.
CircuitDescription
Themotor/generatorcontains3internalcurrentsensors.
ConditionsforSettingtheFault
Themotor/generatorhas3currentsensors(2phase-currentsensorsand1DC-currentsensor).If1ofthese
currentsensorsfails,thefaultisreported.
Note:Thegeneratorcannotoperatewhilethisfaultisactive.Additionally,thecuttingreelmotorsaredisabled
bytheTEC-5002.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Removethemotor/generatorassemblyfromthemachine.
Removethemotor/generatorassemblyfromthemachine.RefertoChapter5ofthe5010-HServiceManual.