Fault27:EngineRunOutputCircuitFault
toFuelActuator
InfoCenterDisplay:
_____ FAULT#27 _____
RunOUT
FaultDescription
The“enginerun”outputcircuitfromtheTEC-5002issupplyingtoomuchcurrenttothefuelactuator.The
TEC-5002issensingthattheoutputsignaltothefuelactuatorisabovethemaximum.
Note:ThefuelactuatorisalsoreferredtoastheeGov.
CircuitDescription
ThefuelactuatorandtheTEC-5002controllerworktogethertomaintainenginespeedbyadjustingthefuel
deliverytotheengine.Asensorinthemotor/generatorprovidesasignalforgenerator/enginespeedtothe
TEC-5002throughtheCANbus.Iftheenginespeedchangesbecauseofchangestotheloadontheengineor
becausetheoperatorofthemachinechangesenginespeed,theTEC-5002modiestheelectricaloutputto
thefuelactuator,thentheactuatoradjustsfuelassignaledbytheTEC-5002tomaintainenginespeed.The
TEC-5002monitorstheoperationofthefuelactuator.
Note:Ifaproblemoccurswiththefuelactuatororcircuitwiring,theextensionspringbetweentheactuator
bracketandenginespeedcontrollevermovesthecontrollevertohighidle(3,150rpm)withtheengine
mechanicalgovernorcontrollingenginespeedabovehighidle.
ConditionsforSettingtheFault
TheTEC-5002reportsfault27ifanyofthefollowingconditionsaremet:
•theoutputsignalfromtheTEC-5002tothefuelactuatorisabovethemaximum.
•thesignalcannotreachthefuelactuator(duetodamagedwiring).
•thefuelactuatoriswornordamaged.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Testthefuelactuator.
1.Openthehoodandlocatethefuelactuator.SeeFigure61.
89