Fault9:12VdcChargingSystemVoltage
TooLow
InfoCenterDisplay:
_____ FAULT#9 _____
ChargingLO
FaultDescription
TheTEC-5002hasdeterminedthatthe12Vdcchargingsystem(alternator)isgeneratingavoltageless
than8.8Vdc.
CircuitDescription
A12Vdcbatterymountedattherearofthemachineandtheenginealternatorprovidesystemelectricalpower.
ConditionsforSettingtheFault
TheTEC-5002detectsthatthe12Vdcchargingsystem(alternator)isproducingavoltagethatistoolow.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Checkthealternatordrivebelt.
1.Locatethealternatorontheright-handsideoftheengine,neartherearofthemachine.SeeFigure33.