EasyManua.ls Logo

Toro Reelmaster 5010- H - Fault 79: 48 V Key Switch Undervolt-CRM 4

Toro Reelmaster 5010- H
476 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault79:48VKeySwitchUndervolt—CRM4
Important:Forthisfault,theterm“keyswitch”referstothe48Vdclogicpowercircuit,nottothe
ignitionswitch.
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5002shutsofftheother4
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____ FAULT#79 _____
48V LOV 4
FaultDescription
Akeyswitchundervoltagefaultisreportedwhenthecuttingreelmotormeasuresasystemvoltagelower
than32Vdc.
CircuitDescription
Eachcuttingunithasanelectriccuttingreelmotorthatcontainsaninternalcontroller.Theinternalcontroller
measures48Vdclogicpower,andtheelectriccuttingreelmotormeasures48Vdcbuspower.
Ifonly1cuttingreelmotorisreportingakeyswitchundervoltfault,theproblemismorelikelytobewiththe48
Vdclogicpowerconnectiontothatcuttingreelmotor.
Ifmorethan1cuttingreelmotorisreportingakeyswitchundervoltfault,theproblemismorelikelytobe
withthe48Vdcbusvoltage.
ConditionsforSettingtheFault
Cuttingreelmotor4detectsthatthe48Vdclogicvoltageisbelowtheminimumof32Vdcandsetsthisfault.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Determinethetroubleshootingstrategy.
Ifonly1cuttingreelmotorisreportingakeyswitchundervoltfault,theproblemismorelikelytobewiththe
48Vdclogicpowerconnectiontothatcuttingreelmotor.GotoStep3.
296

Table of Contents

Other manuals for Toro Reelmaster 5010- H

Related product manuals