Fault46:SoftwareIncompatible—CRM2
Note:Theenginecannotstartwhilethisfaultisbeingreported.
InfoCenterDisplay:
_____ FAULT#46 _____
SoftwareIncompatible
2
FaultDescription
Thecontrollersoftwareincuttingreelmotor2isincompatiblewiththesoftwareintheTEC-5002controller.
CircuitDescription
Therearemultiplecontrollerslocatedthroughouttheelectricalsystemonthismachine,includingtheTEC-5002
mastercontrollerandindividualcontrollerswithineachcuttingreelmotor.Thereareadditionalindividual
controllerswithinthemotor/generatorunitandtheInfoCenter.Allthesecontrollersmusthavecompatible
softwareforthemachinetofunctioncorrectly.
ConditionsforSettingtheFault
Ifthecontrollersoftwareincuttingreelmotor2isincompatiblewiththesoftwareintheTEC-5002controller,this
faultisreported.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:UseToroDIAGtoreprogramthemachine.
UseToroDIAGtoreprogramthemachine.Iftherstattempttoreprogramthemachineisunsuccessful,try
reprogrammingthemachineasecondtime.
1.ConnectaPCwithToroDIAGsoftwaretothemachineviaaToroDIAGCable(PartNo.115-1944).Refer
toToroDIAG-QuickStart(page24).
2.UsetheToroDIAGsoftwaretoreprogramthemachineinaccordancewithToroDIAGUser’sGuide.The
cuttingreelmotorisreprogrammedduringthereprogrammingofthemachine.
3.DisconnecttheToroDIAGcablefromthemachine.
165