Pass
Ifreprogrammingthemachinewassuccessful,gotoReturningtheMachinetoService(page22)
andfollowthestepslisted.
Fail
Ifbothattemptstoreprogramthemachineareunsuccessful,gotoStep3.
Step3:Inspectthewiringforcuttingreelmotor2.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.
2.Unplugthe48Vdcbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnecting
andDisconnectingthe48VdcBatterySystem(page19).
3.RefertoFigure99tolocatecuttingreelmotor2.
g032972
Figure99
1.Cuttingunit1,whichincludescuttingreelmotor14.Cuttingunit4,whichincludescuttingreelmotor4
2.Cuttingunit2,whichincludescuttingreelmotor25.Cuttingunit5,whichincludescuttingreelmotor5
3.Cuttingunit3,whichincludescuttingreelmotor3
4.Followthecuttingreelmotorcablefromcuttingreelmotor2totheconnectorplatemountedonthe
tractionunit.
Note:The2cuttingreelmotorcableconnectorsaresecuredwithclipstotheconnectorplate.The2
mainharnessconnectorsarenotsecuredtotheconnectorplate.
5.DisconnectmainharnessconnectorsP38andP39fromthecuttingreelmotorcableconnectors.
6.Inspectthe2cuttingreelmotorcableconnectorsandthe2mainharnessconnectorsfordamage,
corrosion,debris,andproperalignmentofthepinsinsidetheconnectors.
Pass
Thewiringinspectionpassed.GotoStep4.
Fail
Oneormoreoftheinspectionchecksfailed.Repairorreplacethewornordamagedparts.Goto
ReturningtheMachinetoService(page22)andfollowthestepslisted.
Step4:TesttheCANbuswiringinmainharnessconnectorP38.
Useamultimetertotesttheresistancebetweenthefollowingpairoflocations: