5.Unplugthe48Vdcbatterydisconnect(Figure7).
g032653
Figure7
6.Afterservicingorrepairingthe48Vdcsystem,applyacoatofdielectricgreasetothecontactsurfacesof
thebatterydisconnectandconnectthebatterydisconnect.
7.Lowertheoperator’sseatandsecureitwiththeseatlatch.
ReadingFaults
TheInfoCenterdisplayshowsinformationaboutyourmachine,suchasfaults,thechargelevelofthe12
Vdcbatteryandthe48Vdcbatterypack,andvariousdiagnosticmessagesandiconsthatprovidecurrent
informationaboutthemachine.
Youcanreadfaults2ways:ontheInfoCenterdisplay(Figure8)oronaPCusingToroDIAGSoftware(page
9).ThissectionfocusesontheInfoCenterdisplay.
20