Fault17:TheReelEnableOutputisOver
Current
InfoCenterDisplay:
_____ FAULT#17 _____
EnableOut
FaultDescription
ThemeasuredreelenableoutputvoltageoftheTECisbeyondtheupperlimits.
Important:Thereelengage/disengageswitchisalsoreferredtoasthecuttingunitenable/disable
switchandasthePTOswitch.
CircuitDescription
Thecuttingunitenable/disableswitchisusedtocontrolwhetherthecuttingreelmotorsareallowedtooperate.
ConditionsforSettingtheFault
TheTEC-5002detectsthatthereelenableoutputvoltageoftheTECisbeyondtheupperlimits.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page21).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.