g032844
Figure104
1.InfoCenterretainingring
3.LifttheInfoCenteroutofthecontrolarm.
4.InsertthereplacementInfoCenterintothecontrolarm.
5.SecuretheInfoCenterwiththeretainingring.
6.ConnectseatharnessconnectorP52totheInfoCenter.
Step7:UseToroDIAGtoprogramtheInfoCenter.
1.ConnectaPCwithToroDIAGsoftwaretothemachineviaaToroDIAGCable(PartNo.115-1944).Refer
toToroDIAG-QuickStart(page24).
2.UsetheToroDIAGsoftwaretoreprogramthemachineinaccordancewithToroDIAGUser’sGuide.The
replacementInfoCenterisprogrammedduringthereprogrammingofthemachine.
3.DisconnecttheToroDIAGcablefromthemachine.
4.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
ComponentLocationandElectricalConnections
TheInfoCenterislocatedatthetop,frontofthecontrolarm.
TheToroDIAGcableportislocatedinsidetheaccesspanelonthecontrolarm.