Pass
Thewiringbetweenthecontrollerandthemotor/generatorpassedinspection.GotoStep5.
Fail
Thewiringbetweenthecontrollerandthemotor/generatordidnotpassinspection.Onlyrepair
wiringthathasworninsulationorarecessedconnectorpin.Replaceallcomponentsthathave
damaged,burned,orbrokenwiring.GotoReturningtheMachinetoService(page22)andfollow
thestepslisted.
Step5:Installareplacementcontrollerontothemotor/generator.
RefertoChapter5ofthe5010-HServiceManualandfollowthestepslisted.
Step6:Installthemotor/generatorassembly.
RefertoChapter5ofthe5010-HServiceManualandfollowthestepslisted.
Step7:UseToroDIAGtoprogramthemotor/generator.
1.Removetheaccesspanelfromtheoutercoverofthecontrolarm.
2.ConnectaPCwithToroDIAGsoftwaretothemachineviaaToroDIAGCable(PartNo.115-1944).Refer
toToroDIAG-QuickStart(page24).
3.UsetheToroDIAGsoftwaretoreprogramthemachineinaccordancewithToroDIAGUser’sGuide.The
replacementmotor/generatorisprogrammedduringthereprogrammingofthemachine.
4.DisconnecttheToroDIAGcablefromthemachine.
5.Installtheaccesspanelontotheoutercoverofthecontrolarm.
6.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
218