g033256
Figure12
1.Fasteners
3.ConnectorP75
2.Screw
5.RemovetheTEC-5002fromthemachine.
6.AligntheholesinthereplacementTEC-5002controllerwiththeholesinsidethecontrolarm.
7.SecuretheTEC-5002controllertothecontrolarmwiththe4fastenersthatyouremovedinsubstep4.
8.PlugconnectorP75intotheTEC-5002andsecuretheconnectorwiththescrewthatyouloosenedin
substep3.WhenconnectingtheharnessplugtotheTECcontroller,torquetheretainingscrewto25–28
in-lbs.
9.Aligntheoutercovertothecontrolarmandsecurethecoverwiththe6fastenersthatyouremovedin
substep1.
UseToroDIAGtoProgramtheTEC-5002.
1.ConnectaPCwithToroDIAGsoftwaretothemachineviaaToroDIAGCable(PartNo.115-1944).Refer
toToroDIAG-QuickStart(page24).
2.UsetheToroDIAGsoftwaretoreprogramthemachineinaccordancewithToroDIAGUser’sGuide.The
replacementTEC-5002isprogrammedduringthereprogrammingofthemachine.
3.UsetheToroDIAGsoftwaretorestorethetimersandcounterslefromtheoriginalTEC-5002controller
intothereplacementTEC-5002,inaccordancewiththeControllerReformattingsectionoftheToro
DIAGUser’sGuide.
4.DisconnecttheToroDIAGcablefromthemachine.
5.Installtheaccesspanelontotheoutercoverofthecontrolarm.
6.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
27