EasyManua.ls Logo

Toro Reelmaster 5010- H - Page 306

Toro Reelmaster 5010- H
476 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LocationHarness
Connector
Pin
Wire
Color
Expected
Reading
ConnectorGraphic
1MainP452
Black
(48V
Ground)
2MainP374
Black
(48V
Ground)
Lessthan
2ohms
1MainP441White
2MainP452
Black
(48V
Ground)
24kto26k
ohms
Pass
Theresistancetestspassed,butthevoltagereadingsinStep4arestillbad.
Note:DonotgotoStep6untilafterthevoltagereadingsinStep4aregood.
Fail
Oneormoreofthepowerandgroundwiringtestsfailed.Repairorreplacethewornordamaged
parts.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
Step6:Swapcuttingreelmotorsbetweencuttingunits.
Allofthecuttingreelmotorsareidentical.
1.GotoPreparingforTroubleshootingand/orT esting(page22)andfollowthestepslisted.
2.Unplugthe48Vdcbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnecting
andDisconnectingthe48VdcBatterySystem(page19).
3.Swapcuttingreelmotor5withacuttingreelmotorfromadifferentcuttingunit.Youcanobtainmore
informationonreplacingthecuttingreelmotorinChapter5ofthe5010-HServiceManual.
4.Pluginthe48Vdcbatterydisconnect.RefertoConnectingandDisconnectingthe48VdcBatterySystem
(page19).
5.Operatethemachine.
Thefaultmovestothe
newposition.
Ifthefaultfollowsthecuttingreelmotortothenewcuttingunit,replacethe
cuttingreelmotor.GotoStep7.
Thefaultstopped
repeating.
Ifthefaultnolongerrepeats,notethepositionchangeofthecuttingreelmotor
inthemaintenancerecordsforthemachine.Shouldthefaultrepeatinthe
future,troubleshootingmayberesumedwhereyouleftoff.GotoReturning
theMachinetoService(page22)andfollowthestepslisted.
Step7:UseToroDIAGtoprogramthereplacementcuttingreelmotor.
1.Removetheaccesspanelfromtheoutercoverofthecontrolarm.
2.ConnectaPCwithToroDIAGsoftwaretothemachineviaaToroDIAGCable(PartNo.115-1944).Refer
toToroDIAG-QuickStart(page24).
306

Table of Contents

Other manuals for Toro Reelmaster 5010- H

Related product manuals