Loading...
Thefaultmovestothe
newposition.
Ifthefaultfollowsthecuttingreelmotortothenewcuttingunit,replacethe
cuttingreelmotor.GotoStep7.
Thefaultstopped
repeating.
Ifthefaultnolongerrepeats,notethepositionchangeofthecuttingreelmotor
inthemaintenancerecordsforthemachine.Shouldthefaultrepeatinthe
future,troubleshootingmayberesumedwhereyouleftoff.GotoReturningthe
MachinetoService(page22)andfollowthestepslisted.
Step7:UseToroDIAGtoprogramthereplacementcuttingreelmotor.
1.Removetheaccesspanelfromtheoutercoverofthecontrolarm.
2.ConnectaPCwithToroDIAGsoftwaretothemachineviaaToroDIAGCable(PartNo.115-1944).Refer
toToroDIAG-QuickStart(page24).
3.UsetheToroDIAGsoftwaretoreprogramthemachineinaccordancewithToroDIAGUser’sGuide.The
replacementcuttingreelmotorisprogrammedduringthereprogrammingofthemachine.
4.DisconnecttheToroDIAGcablefromthemachine.
5.Installtheaccesspanelontotheoutercoverofthecontrolarm.
6.GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
ComponentLocationandElectricalConnections
Cuttingreelmotor4islocatedinthefront,leftposition.Thereare2electricalconnectionstothecuttingreel
motor:P48(4wire)andP49(2wire).