3. ON LINE MODE EO13-33002
3.5 Automatic Calibration Setting
3- 10
6. This function is available only when the media pitch is 10.0 mm to 150.0 mm.
7. When a label end or head open error occurs during an automatic calibration, the printer stops, resulting in an
error.
8. During an automatic calibration, the ribbon motor is rotated. Even if the ribbon is not loaded, this function
does not result in an error. However, the print condition will be automatically changed to “No ribbon” after the
calibration ends.
9. When the cutter is installed and a previous issue was performed in cut issue mode, paper is cut and ejected
after automatic calibration completes
10. When the automatic calibration is in operation, paper does not stop at a strip position even in strip or special
strip mode.
11. When the automatic calibration is in operation, ribbon saving function is disabled even if its parameter is set to
ON.
12. When the printing speed is set to 8”/sec. it will be automatically changed to 4”/sec. during an automatic
calibration.
13. An automatic forward feed is not performed immediately after an automatic calibration, even if the auto forward
wait parameter is set to ON.