ADJUSTMENT
6 - 19
[D] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) Press [FAX] [START] to make a copy at the mode of A3 (LD), 100% and the 2nd drawer.
(4) Measure the distance C from 10 mm to 210 mm of the copied image of the ruler.
(5) Check if the distance C is within the range of 200±0.5 mm.
(6) If not, use the following procedure to change values and repeat steps (3) to (5) above.
(Adjustment Mode) (Key in the code [3032]) [START]
(Key in a value (acceptable values: 0 to 255))
Press the [OK] or the [INTERRUPT] button (stored in memory).
(“100% A” is displayed.)
* The smaller the adjustment value is, the lower the reproduction ratio becomes (0.05 mm/
step).
Fig. 6-19
200 250 300 350 40050 100 150
C
Feeding direction
Copied image of the ruler