PREVENTIVE MAINTENANCE (PM)
7 - 29
* 16. Transfer belt cleaning bush/Flicker periphery
When replacing the transfer belt cleaning brush, clean the toner pooling under the brush
(around the flicker).
Fig. 7-27
* 17. Upper separation finger
The paper jam may be caused if the tip of the finger is damaged or deformed. If there is
any problem with it, replace the finger with a new one regardless of the number of copies
which have been made.
Do not damage the tip of the finger during the cleaning. The finger may be damaged if the
toner adhering to the tip of it is scraped off forcibly. Replace the finger if the toner is
sticking to it heavily.
* 18. Cleaning web/web pushing roller
Be sure to replace both of the cleaning web and the web pushing roller at the same time,
since the cleaning web may be caught by the web pushing roller if this roller is
continuously used.
Flicker
periphery