INSTALLATION INSTRUCTION
TEMPERATURE CONTROL REPLACEMENT CONTINUED.......
___________ STEP 8 ___________
Unplug the cooler
___________ STEP 9 ___________
Checking Relay Operation:
A. Unplug the condensing unit from
the compressor receptacle ( located
on the ballast box).
B. Turn the new control to the “0”,
(zero), position by aligning the zero
indication on control knob with the
arrow stamped into the evaporator
housing. Ensure that control is off
by listening for an audible click.
This will indicate an off position.
C. Plug voltmeter into compressor
receptacle.
D. Plug cabinet into power source.
Securing Ballast Box:
A. Reinstall ballast box cover.
B. Anchor cover with two screws.
F. Check voltage at compressor
receptacle. Voltage should equal
voltage at wall outlet.
G. If voltage is correct, turn temper-
ature control to “0”, (zero).
H. Plug condensing unit cord back
into the compressor receptacle.
___________ STEP 10 ___________
Replacing Louvered Grill:
A. Reinstall grill by reversing earlier
procedure.
___________ STEP 11 ___________
Re-connect Power Cord.
___________ STEP 12 ___________
Return Temp Control to normal
setting, and check cabinet
operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the True GDM Series and is the answer not in the manual?

True GDM Series Specifications

General IconGeneral
Defrost TypeAutomatic
WeightVaries by model
ShelvesAdjustable Wire Shelves
LightingLED
Interior FinishStainless Steel
Compressor LocationBottom
Energy EfficiencyEnergy Star Certified
CapacityVaries by model
DimensionsVaries by model

Related product manuals