EasyManuals Logo

Universal Robots UR5 Original Instructions

Universal Robots UR5
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
13.20 Command: Event
13.20 Command: Event
An event can be used to monitor an input signal, and perform some action or set a
variable when that input signal goes high. For example, in the event that an output
signal goes high, the event program can wait for 200ms and then set it back to low
again. This can make the main program code a lot simpler in the case on an external
machine triggering on a rising flank rather than a high input level. Events are checked
once every control cycle (8ms).
Version 3.1 (rev. 17782)
Copyright © 2009-2015 by Universal Robots A/S. All rights reserved.
II-69 CB3

Table of Contents

Other manuals for Universal Robots UR5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots UR5 and is the answer not in the manual?

Universal Robots UR5 Specifications

General IconGeneral
BrandUniversal Robots
ModelUR5
CategoryRobotics
LanguageEnglish

Related product manuals