Connect external sensor to thermostat
Note
For accurate temperature: attach the outdoor sensor to
the north side of the building where it is unlikely to be
exposed to direct sunlight. Do not place it close to doors,
windows, or air outlets.
1. Insert the two wires from the sensor cable (non polarized) into
the removable connector.
2. Tighten the screws fixing the wires in the connector.
3. Insert the connector on the input pegs on the thermostat.
When used as a regular thermostat the external sensor terminal can
be used to connect a floor temperature sensor, an outdoor
temperature sensor, or a remote temperature sensor. Use the DIP
switches on the thermostat to select function mode.
DIP switch
Caution!
The DIP switch in the thermostat must be set before it is
registered.
Caution!
The switches must be set to one of the available
functions, otherwise the thermostat cannot be registered.
Set the DIP switch according to the function of the thermostat.
Thermostat function Switch
Room temperature sensor
Room temperature sensor and floor temperature
sensor
Room temperature sensor and outdoor temperature
sensor
Remote sensor
Start the thermostat
Remove the plastic transportation strips from the batteries to start the
thermostat.
The thermostat use two alkaline 1.5 V AAA batteries which provides
about 2 years of battery life, as long as it is positioned within radio
range of the room controller. Ensure that the batteries are correctly
inserted in the thermostat.
The thermostat will perform a self test, for about 10 seconds, when
starting up. The system will be blocked for input and the thermostat
LED flashes during this period.
Uponor Smatrix Wave PULSE
|
Installation and operation manual
|
37